Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes
Diabetology & Metabolic Syndrome volume 8, Article number: 48 (2016)
Abstract
Background
Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool.
Methods
This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian® REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3–7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application.
Results
HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant.
Conclusion
Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it was not associated with improvement in glycemic control or pregnancy outcomes.
Background
Gestational diabetes mellitus, the most common complication of pregnancy, is usually diagnosed between 24 and 28 weeks of gestation. Within this narrow window of time, women with GDM are required to control their blood glucose swiftly after diagnosis to minimize adverse pregnancy outcomes. This requires disease awareness and self-control of blood glucose; however, these women usually have no experience and less knowledgeable in diabetes management and glycemia self-control.
A real time-Continuous Glucose Monitoring System provides the patient with continuous information about the alterations in the blood glucose levels throughout the day, which is immediately revealed to the patient, and helps the patient to understand how food, exercise, and insulin affect blood glucose [1]. This visibility may empower the patient to modify his/her lifestyle and engage in therapeutic management [2]. Nonetheless, RT-CGMS requires extra effort from patients and entails careful understanding on how to react according to the fluctuations of blood glucose levels. Using RT-CGMS, similar to the use of any other technology, requires sensible device utilization to obtain the optimal benefits from the system. The system also requires counseling support and encouragement by healthcare professionals. RT-CGMS studies in non-pregnant type 1 and type 2 diabetes patients reported its efficacy in improving glycaemic control [3–6]. In addition, intermittent use of retrospective CGM in pregnant women with pregestational diabetes [7] or GDM [8] was associated with improvement in blood glucose and pregnancy outcomes. However, Secher et al. [9] found that the use of intermittent RT-CGMS in pregnant women with well controlled pregestational diabetes did not improve glycemic control or pregnancy outcomes. There have been no studies evaluating the use of RT-CGMS in patients with GDM. The purpose of this study was to evaluate the impact of a single application RT-CGMS on maternal glycemic control and pregnancy outcomes for patients with GDM in comparison to the standard care and to assess its usefulness as an educational and motivational tool.
Methods
A total of 130 pregnant women diagnosed with GDM attending antenatal services at Maternity and Children Hospital, Madinah, Saudi Arabia from October 2011 to June 2014 were included in the study. Women were eligible if they were diagnosed with GDM in the current pregnancy, had a singleton pregnancy, planned to give birth at the study hospital and were able to give written consent to participate. Exclusion criteria included pre-existing diabetes, multiple pregnancies, chronic diseases and drugs that might affect pregnancy outcome. The study was approved by the ethics committees of the Deanship of Scientific Research, Taibah University Medina, Saudi Arabia, and the Maternity and Children Hospital, Medina, Saudi Arabia. All women consented to participate after receiving a comprehensive explanation of the study.
Demographic data were obtained from all women during the first antenatal visit. Then, women were examined and weight, height, body mass index (BMI) and blood pressure were recorded. Oral glucose tolerance test were performed to all participants between 24 and 28 weeks of gestation. The diagnosis of GDM was based on the recommendations of the International Association of Diabetes in Pregnancy Study Groups (IADPSG). A specialist team consisting of obstetricians, internal medicine physicians, a diabetic educator, and a dietician followed the participants. Glucose values were evaluated weekly from self-monitoring of blood glucose (SMBG) four times per day, fasting and 2 h post meal, for the duration of the study. All participants were provided with a glucometer (Easy max). Glycemic targets were based on ADA recommendations as follows: fasting glucose ≤5.2 mmol/L (95 mg/dL); ≤7.8 mmol/L (140 mg/dL) 1-h post-meal; or ≤6.7 mmol/L (120 mg/dL) 2-h post-meal [8]. If the glucose values were persistently above the glycemic target on three or more occasions during the 1–2-week period, insulin was prescribed.
Patients were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian® REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3–7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). A random, computer-generated number list was used to assign patients to either the SMBG or RT-CGMS group.
Patients in the CGMS group were instructed to come to the research clinic in the morning after fasting for at least 4 h. Glucose sensors were inserted into the subcutaneous tissue at the upper buttock by the same trained nurses. Patients were instructed to continue performing SMBG four times daily and enter all blood glucose values directly into the RT-CGMS for calibration. The patients were also asked to record glucose values, time and contents of meals, insulin injections, exercise periods and symptomatic hypoglycaemic events in a logbook. Patients were allowed to look at their glucose value in the monitor and patients were encouraged to react appropriately. At the end of the monitoring period, the RT-CGMS results were downloaded into a computer and glucose profiles were generated. Subsequently, the resulting glucose profiles were reviewed by the researchers, and the treatment plan was adjusted accordingly. Daily mean sensor readings, SD of blood glucose, and the area under the curve for hyper and hypoglycaemia were noted from the RT-CGMS report. The values of these readings were compared between the first and last day of RT-CGMS application. Hypoglycaemia was defined as glucose values below 3.3 mmol/L (60 mg/dL), and hyperglycaemia was defined as glucose at or above 7.8 (140 mg/dL) mmol/L. Side effects from RT-CGMS were noted, e.g., skin irritation from the sensor. Acceptability of RT-CGMS by the patients was verified.
Patients in both groups were followed until delivery. Follow up frequency depended on the blood sugar control and week of gestation.
At the end of the pregnancy, the differences in diabetes control between the two groups were assessed by HbA1c, mean fasting and postprandial glucose levels, number of women needed insulin and total daily insulin dose. All measurements of serum glucose were performed by the glucose oxidase method. Formal laboratory HbA1c measurements were assessed by standardized HPLC.
Maternal and neonatal outcomes were collected after delivery from participants medical records and comparisons were made between the two groups.
Neonatal hypoglycaemia was defined as a blood glucose level below 2.2 mmol/L (40 mg/dL). An Apgar score >7 at 5 min was considered acceptable.
Statistics
Statistical analyses were performed using SPSS software (v 16.0; SPSS Inc, Chicago, IL). Fisher’s exact test and χ2 analysis were performed to test for differences in the proportions of categorical variables between the two groups. Student’s t test (two-tailed) was used to determine the significance of differences between two continuous variables. A paired t test was used to determine the significance of differences in the parameters of glucose variability between the first day of sensor application and the last day. P < 0.05 was taken as the cut-off value for significance.
Results
In total, 130 pregnant women were enrolled in the study. Eight patients were excluded from the RT-CGMS group as no glucose reports could be downloaded from the system. In two cases, this occurred because of sensor failures, in two other cases the electrodes fell of, and in four cases the patients did not perform calibration. Overall, 122 women completed the study, 60 in the RT-CGMS group and 62 in the SMBG group (Fig. 1).
Maternal baseline characteristics are shown in Table 1. There were no significant differences between the two groups. Baseline HbA1c and glucose levels at fasting, 1 and 2-h during OGTT were comparable.
Real time-continuous glucose monitoring
The mean gestational age at the time of RT-CGMS’s application was 26 ± 5 weeks. The mean duration of the RT-CGMS registration period was 66.8 ± 2.3 h. As the levels of blood glucose were immediately revealed to the patient, 52.6 % reported some response to correct for hyper or hypoglycaemia, and 48 % received some modifications in their management plan after reviewing the RT-CGMS report by the research team.
RT-CGMS was generally well tolerated and there were no major side effects aside from mild erythema and skin irritation around the sensor’s insertion site. Indeed, the majority of patients (90 %) accepted the RT-CGMS. The reasons for not accepting the system were mainly due to technical challenges, in particular calibration, disparities between the RT-CGMS and SMBG readings, anxiety from continuous awareness of blood glucose levels, and mild local discomfort on laying down as the sensors were placed at the upper outer area of the buttocks.
Parameters of glucose variability
There was significant improvement in the parameters of glucose variability by the last day of sensor application (see CGMS’s report for one patient, Additional file 1: Figure S1). Both mean sensor glucose and SD of the sensor glucose were reduced significantly, P = 0.016 and P = 0.034, respectively (Fig. 2a, b). Although, the area under the curve for both hyper and hypoglycaemia were improved by the last day of sensor application, the results were not statistically significant (Fig. 2c, d).
Glycemic control
HbA1c, mean fasting and postprandial glucose level were comparable between the two groups at the end of the pregnancy. In addition, there were no significant differences in the number of women who required insulin therapy or the total daily insulin dose between both groups, Table 2.
Pregnancy outcomes
Of the 122 pregnancies, there was one miscarriage and 121 live births. Five infants had congenital malformations, with three cardiovascular malformations in the SMBG group and two in the RT-CGM group (one cardiovascular and one anus malformation).
Approximately half of the deliveries were by caesarean section with no differences between the two groups. Similarly, there were no differences in the gestational age at deliveries, birth weight, prevalence of macrosomia and neonatal hypoglycaemia.
There were no statistically significant differences in the other maternal and neonatal outcomes between the two groups, Table 2.
Discussion
To our knowledge, this study is the first prospective study to examine the use of real time CGMS in patients with GDM. We found that a single application of RT-CGMS for pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. It gives the pregnant woman insights on the effect of food, exercise, and insulin on blood glucose, which helps in modifying the patient’s diet and exercise practices. In line with this finding, previous studies have shown the usefulness of RT-CGMS as an educational and a motivational tool for poorly controlled type 1 [3, 4] and type 2 diabetes.[6].
Blood glucose variability has a significant impact on the quality of life and appears to be associated with the development of diabetes complications [11]. A reduction in glycemic variability alone was suggested to improve diabetes outcomes even with no improvement in HbA1c [11]. In the present study, there was significant improvement in blood glucose variability with a single application of RT-CGMS to GDM patients. This is in line with previous studies that used RT-CGMS in type 1 and type 2 diabetic patients [4–12] and other studies that used retrospective CGMS in patients with GDM [8]. In the current study, mean glycaemia, SD of mean glycaemia, and the area under the curve for both hyper and hypoglycaemia were used to assess the glycemic variability, and we found significant improvement in the mean glycaemia and the SD of mean glycaemia by the last day of RT-CGMS application. The area under the curve for both hyper and hypoglycaemia were also improved; however, the results were not statistically significant.
Despite the improvements in glycemic variability during RT-CGMS application, there were no differences in glycemic control between the RT-CGMS and the standard antenatal care group at the end of pregnancy. This is in agreement with a study by Yu et al. in which the researchers found significant improvements in glycemic variability; however, the mean blood glucose levels were similar between the CGM and the routine care group and the researchers study did not evaluate HbA1c at the end of the pregnancy [8]. In addition Secher et al. [9] did not find improvement in glycemic control when applying RT-CGMS intermittently to pregnant women with well-controlled type 1 and type 2 diabetes. This is also in line with a study on well-controlled non pregnant diabetic patients in whom there was no additional improvement in HbA1c with RT-CGMS application [13].
On the other hand, some studies have demonstrated the effectiveness of RT-CGMS on glycemic control in non-pregnant patients with type 1 or type 2 diabetes [4–12] as well as the uses of intermittent retrospective CGM in patients with pregestational diabetes [7]. In those studies, participants had higher HbA1c at baseline compared to the participants in our study and other studies with negative results. This might explains the disagreement between the findings. As the level of HbA1c tends to decrease in pregnancy due to the rise in red cell mass and red blood cell turnover, the use of HbA1c to assess glycemic control in GDM women with low HbA1c levels at the initial visit may not be useful [14]. The mean baseline HbA1c in our cohort of women was 40 mmol/mol [range 31–49], (5.8 %) [range 5–6.7], which might explain our negative results on HbA1c.
Our finding of the lack of effectiveness of RT-CGMS on pregnancy outcomes was in agreement with a study by Secher et al. in which RT-CGMS was used in pregnant women with well-controlled type 1 and type 2 diabetes [9], and is in contrast to the findings from the other studies that confirmed the improvement in pregnancy outcomes when using retrospective CGM in patients with pregestational diabetes [7] or GDM [8]. Murphy et al. [7] found lower birth weight and lower risk of macrosomia when using retrospective CGM intermittently in patients with pregestational diabetes, and Yu et al. [8] found less risk of preeclampsia and caesarean deliveries, lower birth weight, and less neonatal complications when using retrospective CGM intermittently on GDM patients.
The reason for the disagreement between the studies on the effect of CGMS on glycemic control and pregnancy outcomes can be attributed to several factors, including baseline glycemic control, size of the study sample, duration of CGM application, and patient selection. Well-controlled diabetic patients at baseline may have no further benefits from using CGM. The smaller the study sample size the lower the power for finding significant results. Indeed, we found lower levels of HbA1c and mean fasting and postprandial glucose along with lower doses of insulin in the RT-CGMS group than in the standard group; however, the results did not reach statistical significance. In addition, longer application of RT-CGMS may give better results than shorter usage, as there is a learning curve for women using the system. Finally, patient selection is an extremely important factor. Without a doubt, the key issue for RT-CGMS success is selecting appropriate patients. Highly motivated patients who have an interest in using this technology and are enthusiastic to react accordingly will benefit most from using the system. If the patient is reluctant to respond to the data delivered by RT-CGMS, the system will be useless. This was illustrated by a study that applied RT-CGMS for one month to T1DM adolescent patients. Although they found significant improvement in glycemic control, the use of this technology was not efficient for those with a very high HbA1c [HbA1c >86 mmol/mol (10 %)] at baseline, in whom compliance and self-motivation are the main concerns [4]. Therefore, we still believe in the favourable effects of RT-CGMS in patients with diabetes if applied to the right person.
RT-CGMS was accepted by most of the participants, and the reasons for non- acceptance were technical challenges, such as calibration and frustration with sensor alarms, anxiety from continuous awareness of blood glucose level, skin reaction, and disparities between RT-CGMS and SMBG readings. Admittedly, a significant number of our women had readings in the hypoglycaemic range during the first day of RT-CGMS application, which conflicted with the SMBG reading, a finding that has been reported previously by Secher et al. [9]. This indicates that there is still a need for improvement in the RT-CGMS accuracy in the hypoglycaemic range.
Limitations to the current study include single use of RT-CGMS, which might be the reason for non-improvement in glycemic control or pregnancy outcomes. However, our aim was to test the efficacy of a single application of RT-CGMS in GDM because it is more convenient and acceptable to the patients and less costly. Another limitation of our study is the relatively small sample size, which may have limited the power to detect differences in glycemic control or in pregnancy outcomes. A larger clinical trial with a selection of highly motivated patients is recommended to evaluate the effectiveness of RT-CGMS in pregnant women with GDM. In addition, cost effectiveness studies assessing the application of RT-CGMS in these women versus standard care is also needed.
Conclusions
A single application of RT-CGMS is useful as an educational and a motivational tool for patients with GDM and helps in improving blood glucose variability. However, these changes are not coupled with improvement in HbA1c and pregnancy outcomes. Using RT-CGMS, similar to any other technology, requires sensible utilization of the device to obtain the greatest benefit from the system and the key factor in achieving success is selecting appropriate patients.
References
Klonoff D, Buckingham B, Christiansen J, Montori V, Tamborlane W, Vigersky R, et al. Continuous glucose monitoring: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2011;96(10):2968–79.
Hirsch I. Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist. J Clin Endocrinol Metab. 2009;94:2232–8.
Deiss D, Bolinder J, Riveline J-P, Battelino T, Bosi E, Tubiana-Rufi N, et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care. 2006;29(12):2730–2.
Głowińska-Olszewska B, Tobiaszewska M, Łuczyński W, Bossowski A. Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents. Adv Med Sci. 2013;58(2):344–52.
Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, et al. Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor A randomized controlled trial. Diabetes Care. 2006;29(1):44–50.
Yoo H, An H, Park S, Ryu O, Kim H, Seo J, et al. Use of a real time continuous glucose monitoring system as a motivational device for poorly controlled type 2 diabetes. Diabetes Res Clin Pract. 2008;82(1):73–9.
Murphy HR, Rayman G, Lewis K, Kelly S, Johal B, Duffield K, et al. Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial. BMJ. 2008;337:a1680.
Yu F, Lv L, Liang Z, Wang Y, Wen J, Lin X, et al. Continuous glucose monitoring effects on maternal glycemic control and pregnancy outcomes in patients with gestational diabetes mellitus: a prospective cohort study. J Clin Endocrinol Metab. 2014;99(12):4674–82.
Secher AL, Ringholm L, Andersen HU, Damm P, Mathiesen ER. The effect of real-time continuous glucose monitoring in pregnant women with diabetes a randomized controlled trial. Diabetes Care. 2013;36(7):1877–83.
Association AD. Standards of medical care in diabetes—2010. Diabetes Care. 2010;33(Supplement 1):S11–61.
Brownlee M, Hirsch IB. Glycemic variability: a hemoglobin A1c–independent risk factor for diabetic complications. JAMA. 2006;295(14):1707–8.
Rodbard D, Bailey T, Jovanovic L, Zisser H, Kaplan R, Garg SK. Improved quality of glycemic control and reduced glycemic variability with use of continuous glucose monitoring. Diabetes Technol Ther. 2009;11(11):717–23.
Group JDRFCGMS. The effect of continuous glucose monitoring in well-controlled type 1 diabetes. Diabetes Care. 2009;32(8):1378–83.
Jovanovič L, Savas H, Mehta M, Trujillo A, Pettitt DJ. Frequent monitoring of A1C during pregnancy as a treatment tool to guide therapy. Diabetes Care. 2011;34(1):53–4.
Authors’ contribution
EA was the primary investigator who was involved in all steps. EO was involved in designing the study, following the GDM patients from medical side and help in writing the manuscript. TB was involved in designing the study, seeing the participants from obstetric side and getting the pregnancy outcome and help in writing the manuscript. All authors read and approved the final manuscript.
Acknowledgements
The authors would like to thank Mrs. Khadija Almohna, Yasmin Bokhari, Amaal Alfadhli, Afrah Turkistani, Fatimah Almohana, and Mr. Khalid Turkistani for their great assistance in the research clinic and data collection.
Competing interests
The authors declare that they have no competing interests.
Funding
This work was supported by a Grant, number AT-30-362, from Taibah University, Medina, Saudi Arabia.
Author information
Authors and Affiliations
Corresponding author
Additional file
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.