Skip to main content

Effectiveness, safety, and preference of transdermal insulin compared to subcutaneous insulin in the treatment of diabetes patients: a systematic review of clinical trials

Abstract

Background

Several studies were performed on transdermal (TD) insulin delivery in vitro and in vivo, and recently, the study groups included a clinical trial in humans. Therefore, this systematic review was conducted to get summary information about the effectiveness, safety, and preferability of TD insulin in comparison with subcutaneous insulin delivery.

Methods

We conducted a thorough search to find studies in the databases Cochrane Library, MEDLINE via PubMed, Web of Science Core Collection, EMBASE, Scopus, Hinari, Medlib, and Magiran until January 2024. We included 18 randomized clinical trials.

Results

Although there are various types of TD delivery methods, the TD insulin delivery methods that have undergone clinical trials are the TD patch, micro needle TD insulin delivery, and TD insulin jet injector. Eighteen studies were conducted on TD insulin delivery, which showed either superior or comparable effectiveness, safety, and preferability of TD insulin in comparison with SC insulin. About eleven out of eighteen studies (61.1%) showed more effective blood glucose control than SC delivery, and the remaining seven studies showed comparable effectiveness with SC delivery. Eleven studies (61.1%) showed equal tolerability of TD insulin versus SC insulin, and seven studies (38.9%) showed more tolerability of TD insulin over SC insulin. In most studies, eleven out of eighteen (61.1%) showed a higher preference for TD insulin delivery over traditional SC delivery; sixth out of eighteen (33.3%) showed equal preferability for TD insulin versus SC insulin; and only one study (5.6%) showed that TD insulin delivery was less preferable than SC insulin.

Conclusion

The review revealed that clinical trials have demonstrated the effectiveness of TD insulin delivery methods such as TD patches, MN-based insulin delivery, and insulin jet injectors compared to traditional SC routes of administration. The studies showed the superior or comparable effectiveness of TD insulin in controlling blood glucose levels. Additionally, TD insulin delivery was found to be equally or more tolerable than SC insulin delivery in all studies. Overall, the majority of studies favored TD insulin delivery over traditional SC delivery methods, highlighting its potential as a preferred option for insulin administration.

Introduction

A collection of metabolic disorders collectively known as diabetes mellitus (DM) are typified by elevated hepatic glucose synthesis and reduced glucose uptake by muscle and fat, leading to an atypical build-up of glucose in the bloodstream, all of which are caused by insufficient insulin production [1,2,3]. Type 1 diabetes (T1D) is caused by an autoimmune reaction that destroys β-cells in the pancreas, which prevents the body from producing enough insulin [4]. Insulin resistance and/or impaired pancreatic β-cell function are the underlying causes of long-term hyperglycemia, a characteristic of type 2 diabetes (T2D) [5]. In 2021, it was predicted that 536.6 million adults between the ages of 20 and 79 will get DM, with 90% of those cases being T2D [6]. According to a world health organization forecast, by 2040, DM is expected to affect roughly 642 million people, and it will rank seventh among all causes of death globally by 2030 [7].

For T1D, strict glucose control with multiple insulin doses is the standard of care; however, hypoglycemia is a common side effect [8]. People with DM are typically told to self-inject insulin through the subcutaneous (SC) route several times a day, which requires extensive self-management and training, with patients often needing to adjust their dosage based on glucose monitoring [9, 10]. Even though exogenous insulin is widely accessible, those who are affected by T1D are still susceptible to both acute and long-term complications because they are unable to consistently achieve euglycemia with current formulations and technologies [11, 12]. Many healthcare professionals and patients are also reluctant to start insulin therapy because of the somewhat inconvenient SC route of administration, negative side effects like weight gain, and other psychosocial factors [13,14,15,16]. Because of this, scientists have looked into less-invasive ways to administer medications based on novel pharmaceutical formulations that maintain hormone stability and guarantee therapeutic efficacy [17, 18]. When insulin is administered orally or through another novel delivery system, needle-related anxiety, injection pain, and potential infections are avoided [19, 20].

There are various novel approaches for the delivery of insulin, including inhaled insulin delivery, oral, colonic, nasal, buccal, transdermal (TD), intra-peritoneal, ocular, rectal, vaginal, etc. [7]. TD drug delivery systems (TDDDS) are appealing due to their numerous advantages, such as utilizing the large surface area of the skin for drug administration and enabling continuous insulin release to stabilize glucose levels over an extended period, thereby reducing the risk of concentration-related side effects [21,22,23,24]. Because of the benefits they provide over invasive injection and oral dosage forms, TD systems have drawn more attention and have been seen as a possible hope for managing diabetes over the past ten years [25]. Various strategies may be used to ensure skin delivery of insulin, such as using fatty acids and surfactants as chemical penetration enhancers to partially disrupt the SC barrier, although they are only effective with small molecules [26]. Moreover, utilizing a variety of penetration-enhancing techniques such as iontophoresis, lipid-based nano-delivery systems, microneedles (MNs), TD films, and patches to ensure adequate TDD of insulin [22, 24, 25]. MNs have become a more appealing alternative due to their proven utility and capacity to mitigate the drawbacks of parenteral and oral drug delivery, and they are small enough to be self-administered without causing pain or discomfort [27, 28].

Transdermal delivery of insulin

The human body’s largest organ is the skin, which is a complex mixture of mesenchymal and epithelial tissue, consisting of a stratified, multilayered epidermis, a dermis with collagen and elastic fibers, underlying SC fat, and adnexal structures like sweat glands, sebaceous glands, and hair follicles [29]. The stratum corneum, epidermis, and dermis are the three layers that make up the skin, which performs the dual roles of an active immune organ and a physical and chemical barrier against foreign invaders [30,31,32]. A vital barrier function of the epidermis is carried out by the stratum corneum [33, 34]. Because SC insulin administration cannot achieve the required portal-systemic insulin concentration gradient, it has limited effects on hepatic glucose suppression [35]. Insulin TD delivery is being investigated in ways such as altering skin barrier characteristics, refining formulations, increasing diffusion coefficients, and applying extra driving forces [30, 36]. The potential of TDDDS to advance medical science with cutting-edge enhancement methods is highlighted by clinical trials looking into TD delivery of macromolecules and vaccines using methods like thermal ablation and MNs [37]. Benefits of MN arrays include minimal trauma, painless delivery, accurate depth control, and different types depending on morphology [38,39,40,41,42]. The structure and composition of TD patches are influenced by the particular drug and release requirements. They are made up of multiple layers that are intended to penetrate the skin and deliver medication [43].

Jet injectors also use the methods of TDDD, which have undergone clinical trials, and usually pressurize the liquid at approximately 20 MPa. To breach the stratum corneum, penetrate the skin barrier, and transport the fluid to the required depths, jet velocities of 100 m/s are required [44]. As a result, jet injections are not constrained by the rates at which various drugs diffuse; they can overcome the drawbacks of other drug delivery techniques, including ablation, iontophoresis, electroporation, sonophoresis, and MNs, although it is challenging to control the jet pressure during drug delivery [33, 45]. Because it is a non-invasive technique that provides the convenience of a TDDDS, this type of insulin delivery is appealing [36]. Therefore, the objective of this study was to synthesize the available evidence on the effectiveness, safety, and preference of TD insulin in comparison with SC insulin.

Methodology

Search strategy

A comprehensive search strategy was conducted using electronic databases, including PubMed, MEDLINE, SCOPUS, CINAHL, Web of Science, EMBASE, Google Scholar, Cochrane Library, ISI, Scopus, Medlib, Irandoc, SID, and Magiran, which were systematically searched online to retrieve related articles. The search terms will include, ((“Diabetes patient”, “Patients with diabetes mellitus”, “Type 1 diabetes”, “Type I diabetes”, “Type 2 diabetes”, “Type II diabetes”, “Type 1 and type 2 diabetes”) and (“Transdermal insulin”, “Transdermal insulin injection”, “Transdermal insulin delivery”, “Cutaneous insulin”, “Microneedle insulin”, “Insulin patch”, “jet injector insulin”) and (“Subcutaneous insulin”, “Subcutaneous insulin delivery”, “SC insulin”, “SQ insulin delivery”) and (“Effectiveness of insulin”, “Outcome of insulin”, “Safety of insulin”, “Adverse effect of insulin”, “Effectiveness and safety of insulin”, “HbA1c”, “Blood glucose”, “Postprandial blood glucose”, “Fating blood glucose”, “AUC of insulin”, “Hypoglycemia”, “preference of insulin”)). Manual searches of relevant journals and conference proceedings were also conducted. The retrieved study references were also screened and checked. The review protocol is available on PROSPERO (ID: CRD42024497023).

Eligibility criteria

The PICO approach (population, intervention, comparator/control, and outcome) was applied for this review. “P” for DM patients, “I” for TD insulin, “C” for SC insulin, and “O” for effectiveness, safety, and preference. This study included clinical trial research that compared the efficacy, safety, and preference of TD insulin compared to SC insulin and that was published in the English language under an open-access system. Reports lacking a full document, abstract, and comparison, however, were not included in the analysis. The titles, abstracts, and comprehensive full-document reviews of the articles were read to assess them.

Data extraction, management, and analysis

Each study’s authors, publication year, design, location, length of time, type of diabetes, inclusion and exclusion criteria, number of patients who finished the study, interventions, outcomes, side effects, and results were extracted, along with study characteristics and patient demographics. If mentioned in the studies, hypoglycemia, the main side effect of insulin, was also thought to be well documented. To find possibly eligible studies, the search results were independently screened by three reviewers. In cases of disagreement among reviewers, a discussion or consultation with an additional reviewer was conducted. Complete text publications from qualified research were located and evaluated for possible inclusion. We sorted the publications according to the types of TDD methods, such as TD patches, MN-based TDD, and insulin jet injectors. The outcome of various TDD methods was evaluated based on their effect on controlling blood glucose (BG), their safety, and their preferred ability by the patient.

Result

In this systematic review, we have searched a total of 1480 articles from all databases. About 271 articles were excluded because of duplication, 1034 articles were excluded because they were out of interest, and 157 articles were excluded because they did not meet the eligibility criteria. Finally, 18 articles that fulfilled the eligible criteria were systematically reviewed [Fig. 1].

Fig. 1
figure 1

PRISMA flow diagram of study selection

Study characteristics

In this study, we included 18 studies that were done in three countries. About eight studies were conducted in the United States of America (USA) [46,47,48,49,50,51,52,53]; one study was conducted in each of the following countries: Germany [54], Israel [55], Australia [61], five studies were conducted in China [56,57,58,59,60], and two studies were performed in the Netherlands [62, 63]. The total sample size was 1044; from them, the maximum sample was from China (657), and the minimum sample was from Australia, which had 10 participants. Of all the studies, two were patch-based delivery, seven were microneedle-based delivery, and ten were jet injectors. The duration of the trial ranged from 3 days to 48 weeks [Table 1].

Table 1 Characteristics of included studies

Effectiveness of transdermal insulin compared with subcutaneous insulin

Although there are various types of TD delivery methods, TD insulin delivery that has undergone clinical trials is the TD patch, MN TD insulin delivery, and TD insulin jet injector. All studies [46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63] showed significant effectiveness in comparison with the usual SC routes of administration. There were about two studies [46, 47] that were based on TD insulin patches; seven studies [48,49,50,51,52,53,54] were based on MN-based insulin delivery; and nine studies [55,56,57,58,59,60,61,62,63] were based on an insulin jet injector. All studies compare the effectiveness, safety, and preference of TD delivery in comparison with SC delivery. All of the studies showed either superior or comparable effectiveness of TD insulin in comparison with SC insulin. About eleven out of eighteen studies (61.1%) [49, 51, 52, 54,55,56,57, 59, 60, 62, 63] showed more effective BG control than SC delivery, and the remaining seven studies [46,47,48, 50, 53, 58, 59] showed comparable effectiveness with SC delivery. Most studies investigated the PH characteristics of TD insulin in comparison with SC insulin delivery, which showed rapid PK characteristics. Twelve studies found that TD insulin has more rapid PK characteristics than SC delivery.

Transdermal insulin patch

There are only two TD patch insulin deliveries that have undergone clinical trials. All of the two studies showed comparable effectiveness, as described in the following paragraphs: Bergenstal et al. [46] reported a 48-week randomized, multicenter interventional trial that compared the efficacy, safety, and self-reported outcomes of basal insulin therapy in 278 adults with T2D who initiated and managed mealtime insulin therapy with a patch pump versus an insulin pen. Glycemic control was assessed using international consensus guidelines for percentages of time in range (%TIR: >70% at 70–180 mg/dL) and time below range (%TBR: 180 mg/dL; 250 mg/dL). Both the patch and pen groups achieved recommended targets in %TIR, but with an increased %TBR.

Another study by Bohannon et al. [47] compared the efficacy, safety, device satisfaction, and quality of life (QOL) in people with diabetes using an insulin bolus patch versus SC delivery. About 38 subjects with diabetes (26 with T1D and 12 with T2D) were randomized to a bolus-patch or SC to deliver mealtime insulin in a multicenter, 6-week crossover study. Using a bolus patch, the mean daily seven-point blood glucose was equivalent to that using SC. Hemoglobin A1c, 1,5-anhydroglucitol, fructosamine, and insulin use were similar between groups.

Microneedle-based transdermal insulin delivery

About seven clinical trials were conducted to compare the effectiveness, safety, and preference of MN-based insulin delivery in comparison with SC insulin delivery. Of them, in four (57.1%) [49, 51, 52, 54] studies, MN insulin has higher effectiveness than SC delivery, and the remaining three [48, 50, 53] show comparable effectiveness. All MN-based TD insulin delivery clinical trials also compared the PK characteristics, and all of them confirmed that MN TD insulin deliveries had more rapid PK properties than SC insulin delivery. A study by Pettis et al. [48] assessed PK and pharmacodynamic [PD] PPG in patients with type T1D after a standardized liquid meal following insulin lispro (IL) or regular human insulin (RHI) given by MN-based intradermal (ID) versus SC delivery. In this randomized, open-label, five-way crossover study, 29 patients received IL and RHI by both the SC and ID routes. The 90-min PPG for ID RHI was 14% lower than SC RHI at 17 min and 11% lower than ID RHI at 2 min. PPG did not significantly differ between ID RHI and SC IL, and ID IL and SC IL. Both ID IL and ID RHI PK data showed significantly faster uptake, Tmax, and Cmax than SC dosing.

A study by Gupta et al. [49] was carried out on two adults with T1D and evaluated bolus delivery of IL using a hollow MN compared to SC delivery. The first phase of the study indicated that MNs led to rapid insulin absorption and a reduction in BG. Bolus insulin delivery followed by consumption of a standardized meal in the second phase revealed that MNs were effective in reducing PPG levels.

Norman et al. [50] studied ID insulin delivery using a hollow MN in comparison with SC delivery. In these repeated measures study, 16 T1D children and adolescents were administered IL in SC and MN on different days. When hollow MN delivery was used instead of SC delivery, insulin onset time was 22 min faster, and offset time was 34 min faster.

Rini et al. [51] conducted a clinical trial to evaluate ID MN insulin kinetics using a randomized, single-center, open-label, two-period crossover study in T1D patients. About 28 patients received treatment during interventional visits: one SC and one ID basal/bolus infusion of insulin aspart [IA] administered over 3 days. ID-bolus infusion was associated with a significantly shorter Tmax and statistically significantly smaller intra-subject variability compared to SC infusion. The PPG response was significantly less pronounced after ID bolus: for most endpoints, ID vs. SC, differences were statistically significant within the 0–1.5 or 0–2 h period.

Gupta et al. [52] compared the PK, pain, and PPG responses of ID IL delivery via a MN versus SC in five T1D subjects. Compared to SC catheters, ID insulin infusion using MN reduced BG levels more quickly and achieved Cmax in about half the time. The use of MN for ID insulin infusion has a rapid PK, which offers great promise for better diabetes control.

Pettis et al. [53] compared the PK and PD of IL delivered via MN ID injection with SC injection in 10 healthy male volunteers who received 10 IU of IL in a randomized crossover fashion. With a quick Tmax and Cmax, MN ID delivery led to a faster absorption of IL, which was associated with faster effects on glucose uptake, more AUC, and a quicker offset of insulin action. Between the administration routes, there was no discernible difference in the relative total insulin bioavailability.

McVey et al. [54] examined the PK and PD effects of IL delivered by SC delivery versus MN-based ID delivery. A total of 22 individuals with T1D participated in the study, which used an eight-arm full crossover block design. The insulin PK endpoints demonstrated faster ID availability than SC insulin. SC administration revealed slight, statistically noteworthy variations in the secondary PD effect.

Jet injector-based transdermal insulin delivery

About nine clinical trials were conducted based on insulin TD jet injectors; most of them (77.8%) [55,56,57, 59, 60, 62, 63] showed higher effectiveness than SC insulin, and the remaining studies [58, 61] showed comparable effectiveness with SC insulin delivery. Kochba et al. [55] conducted a pilot open-label crossover study at a single center with 17 T2D patients to confirm insulin PK may be improved by ID injection. The Tmax for ID injection was significantly shorter than that of SC injection, but the Cmax was not significantly different. The groups’ median insulin AUC was the same. In patients with T2D, ID insulin injection administered via a jet injector showed a better PK profile than conventional SC administration, better insulin coverage during meals, and fewer PPG excursions might result from this.

Ji et al. [56] carried out a study to compare the effects of insulin treatment with a SC delivery and a needle-free insulin injector (NFII) on glucose-lowering effect, tolerability, patient satisfaction, and compliance in patients with T2D. In a prospective, multicenter, randomized, open-label study, 427 patients were enrolled for 16 weeks of treatment. The adjusted mean HbA1c reduction from baseline at week 16 was 0.55% in the NFII group, which was statistically superior and non-inferior to the HbA1c reduction in the SC group.

Jin et al. [57] conducted a study to explore the effect of using a NFII on BG control and well-being index in 42 patients with early-onset T2D using IA. The FBG of the NFII group was lower than that of the SC group. The amount of insulin in the NFII group was lower than that in the SC group, but there was no statistically significant difference. NFII is effective in controlling FBG in patients with early-onset T2D and is less painful at the injection site.

Xing et al. [58] assessed the safety and effectiveness of a NFI in comparison with SC insulin in Chinese T2D patients receiving basal insulin therapy in a multicenter, prospective, randomized, open-label crossover study that included about 62 patients for seven to fourteen days. The FBG control attained by the patients in the SC and insulin NFII groups was comparable. Nonetheless, the NFI group needed less insulin than the SC group to reach the desired FBG level.

Wu et al. [59] demonstrated that both needle injection and NFI can raise HbA1c in T2D patients. About 62 T2D patients received insulin in a self-controlled cross-over study. When patients received NFI instead of needle injections, their BG levels were higher during fasting and post-breakfast. The AUC, or daily blood glucose fluctuation, did decrease during NFI periods. During the NFI period, patients received a lower dose of fast-acting insulin than when they received needle injections. In hospitalized T2D patients undergoing intensive glycemic control, insulin injections without needles provided better glycemic control.

Guo et al. [60] conducted a study to investigate the efficacy of an insulin jet injector and an insulin pen in the treatment of 60 T2D patients treated with RHI and IA in four successive test cycles. RHI and IA administration by the jet injector showed significant decreases in plasma glucose levels as compared to the pen injection. PPG excursions at the time points of 0.5 to 3 h were lower in the jet-treated patients than the pen-treated ones. Postprandial plasma insulin levels were markedly higher in the jet-treated patients than the pen-treated ones. However, the area under the glucose curve in the pen-treated patients was significantly increased as compared to the jet-treated ones. The efficacy of the insulin jet injector in treating T2D patients is superior to that of the insulin pen in regulating plasma glucose and insulin levels.

Reutens et al. [61] carried out an open-label, randomized, crossover pilot study to assess the device preference and tolerability of SC IA delivery and jet injector delivery. Two meal tolerance tests were administered to ten T1D participants one week apart. The results of this small pilot study showed that the devices showed similar glucose excursion, the area under the glucose concentration-time curve for 0–240 min corrected for baseline glucose level, and insulin absorption over the 240-min span.

De Wit et al. [62] conducted a study to determine the effectiveness of jet injection in comparison with SC delivery. A randomized, controlled crossover study was conducted with ten adult patients with T1D and ten with T2D who were overweight. The jet injection significantly decreased the time to peak insulin levels and the hyperglycemic burden during the first two hours. When patients with diabetes who are overweight or obese are given insulin injections, their marked hyperglycemia is corrected more quickly by a jet injection.

Engwerda et al. [63] compared the PK and PD profiles of insulin administration by jet injection versus SC delivery in patients with 12 T1D and 12 T2D patients who received IA by jet injection or by SC in a randomized, double-blind, double-dummy crossover study. When insulin was administered by jet injection, Tmax was shorter, and the hyperglycemic burden was lower during the first hour. For the next five hours, however, the jet injection did not considerably lessen the hyperglycemic burden. Patients with T1D and T2D saw a significant, if modest, decrease in PPG as a result of the significantly faster absorption of insulin following administration by a jet injector. Patients who have trouble controlling PPG excursions may particularly benefit from the enhanced early PPG control.

Safety and participant preference of transdermal insulin in comparison with subcutaneous insulin

As for effectiveness, all studies showed either TD insulin delivery had equal tolerability or more tolerability. Eleven studies (61.1%) [47, 51,52,53,54,55,56,57, 61,62,63] showed equal tolerability of TD insulin versus SC insulin, and seven studies (38.9%) [46, 48,49,50, 58,59,60] showed more tolerability of TD insulin over SC insulin. Most studies, eleven out of eighteen (61.1%) [46,47,48,49,50, 52, 54,55,56, 58, 60] showed a higher preference for TD insulin delivery over traditional SC delivery; sixth out of eighteen (33.3%) [51, 53, 57, 59, 61, 62] showed equal preferability for TD insulin versus SC insulin; and only one study (5.6%) [63] showed that TD insulin delivery was less preferable than SC insulin.

Transdermal insulin patch

One study of TD patch insulin delivery showed comparable tolerability between TD insulin delivery and SC insulin delivery, while the other study showed TD insulin delivery had more tolerability than SC insulin delivery. All TD patch studies were preferable to SC insulin delivery. Bergenstal et al. [46] found that more satisfied patients preferred using the patch, felt less constrained, recommended the patch to others, and felt free to manage their diabetes with the patch over the pen. Their safety was also comparable. Bohannon et al. [47] showed subjects preference for bolus-patch over SC delivery. Both delivery methods had comparable safety, with a similar incidence of non-severe hypoglycemia for both methods.

Microneedle-based transdermal insulin delivery

About four studies (57.1%) [48,49,50,51] of MN TD insulin delivery were well tolerable over SC insulin delivery, while three studies (42.9%) [52,53,54] showed comparable tolerability of MN-based TD insulin delivery versus SC insulin delivery. Moreover, most MN-based TD insulin deliveries (71.4%) [48,49,50, 52, 54] were preferable over SC insulin delivery, and only two studies (28.6%) [51, 53] showed comparable preferability of both delivery methods by patients. A study by Pettis et al. [48] found comparable AEs for both methods of administration. Both of them showed no serious AEs such as headaches, diarrhea, hypoglycemia, or edema, which occurred in three to four patients. Their equal tolerability may implicate their comparable acceptability and preferability.

Gupta et al. [49] found that patients indicated that all MN insulin deliveries were less painful than catheter-based deliveries, which indicated their preference for this method of administration. Subjects indicated a mild tingling sensation during MN delivery, which they attribute to the relatively fast delivery flow rate. Norman et al. [50] found less insertion pain when a single, hollow MN device was used for ID insulin delivery. Pain relief could increase insulin delivery compliance and preference. Rini et al. [51] also investigated that there was no bias in AEs between treatment routes, and ID was safe compared to SC delivery. Pain scores were low for both routes. Patients found infusion set insertion equally acceptable and preferable for both routes.

Gupta et al. [52] found better patient acceptance, which is consistent with the minimally invasive nature of MNs. Additionally, MN caused a lot less pain than catheters. Pettis. et al. [53] showed that all participants experienced safe and well-tolerated ID delivery. During the study, no significant AE was recorded in both methods of delivery, and patients showed comparable preference between both methods of insulin delivery. McVey et al. [54] showed ID delivery preferability and minor variations in pain perception based on route. The number of hypoglycemic events and time in hypoglycemic and hyperglycemic ranges did not significantly differ between routes. No significant AEs were reported in both methods of delivery.

Jet injector-based transdermal insulin delivery

Six Jet injector-based TD insulin delivery studies (66.7%) [55,56,57, 60,61,62,63] showed comparable tolerability with SC insulin, while three insulin Jet injector studies (33.3%) [58,59,60] showed good tolerability over SC insulin delivery. High preferability of jet injector TD insulin delivery over SC insulin delivery was demonstrated by four studies (44.4%) [55, 56, 58, 60], four studies (44.4%) [57, 59, 60, 62] showed equal preferability, and one study (11.1%) [63] showed less preferability of jet injector-based insulin delivery over SC insulin delivery. Kochba et al. [55] investigated no significant difference in insertion pain and AEs between ID and SC injections. ID is more preferable to SC delivery. Ji et al. [56] showed that there was no significant difference in compliance rates between groups due to similar injection miss rates, although they preferred NFII. After 16 weeks, NFII patients had higher treatment satisfaction than SC patients. The incidence of hypoglycemia and unexpected adverse events was similar between groups.

Jin et al. [57] found that pain scores were lower with needle-free syringes vs. SC delivery, and skin bleeds were similar in both groups. They showed comparable preferability in both delivery methods. Xing et al. [58] investigated patients who reported feeling more at ease using the NFI due to its comparable acceptability and ease of use. Additionally, using a NFI considerably lessened their anxiety and pain about injections. Wu et al. [59] found that similar levels of patient satisfaction were reported for the two types of injection devices, both of which were above the general satisfaction threshold. When needle injections were avoided, the level of pain was substantially less than when they were administered.

Guo et al. [60] found that jet-treated patients had no fear about their administration, which showed their preferability for jet injection. They had comparable AEs, and no serious AEs were observed. Reutens et al. [61] investigated and found that no significant AEs were observed and there were no reports of bruises at the device application site. Participants liked using both devices equally. de Wit et al. [62] showed most mild to moderate AEs were related to hyperglycemia, like thirst, polyuria, and nausea, which resolved when glucose levels dropped. Preferability, ease of use, and pain/discomfort levels were comparable between the jet injector and pen. Engwerda et al. [63] found that there were no differences in the need for exogenous glucose, timing, or amount between the jet injector and pen. Pain levels and tolerance were similar. Contrary to all studies, this study showed the preferability of SC insulin delivery.

Discussion

All of the studies demonstrated significant effectiveness, or at the very least, showed comparability with respect to the traditional SC delivery methods. About eleven out of eighteen studies (61.1%) [49, 51, 52, 54,55,56,57, 59, 60, 62, 63] showed more effective BG control than SC delivery, and the remaining seven studies [46,47,48, 50, 53, 58, 59] showed comparable effectiveness with SC delivery. One key finding was that the majority of studies (61.1%) demonstrated superior BG control with TD insulin compared to SC delivery. This suggests that TD insulin may offer better glycemic control for individuals with diabetes. Additionally, the remaining studies showed comparable effectiveness between TD and SC insulin, indicating that TD delivery is at least as effective as SC administration.

Although there are various types of TD insulin delivery methods, the ones that have undergone clinical trials are the TD patch, MN TD insulin delivery, and transdermal insulin jet injector. Furthermore, the study investigated the PK characteristics of TD insulin and found that TD delivery methods generally have more rapid PK profiles compared to SC administration. This suggests that TD insulin may lead to quicker absorption and onset of action, which could be beneficial for managing BG levels effectively. Overall, the findings suggest that TD insulin delivery methods have shown promising results in clinical trials.

The studies demonstrate improved effectiveness, safety, and preferability with TD insulin administration, indicating the potential for this innovative delivery approach to be introduced to the market. Recent research has explored alternative delivery methods to replace the traditional SC route, with several studies highlighting the benefits of TD insulin delivery. There were various promising clinical trials that provided alternative routes of insulin to prevent traditional SC delivery. Akbari et al. (2016) conducted a systematic review and meta-analysis comparing the safety and efficacy of oral insulin delivery to the SC route. The meta-analyses revealed that there were no significant differences between oral and SC insulin in terms of regulating HbA1c, FBG, 1- and 2-hour PPG levels, or insulin Cmax and Tmax. This systematic review and meta-analysis suggest that oral insulin is generally comparable to SC insulin in terms of glycemic efficacy and safety [64]. In comparison with TD insulin delivery, which is often considered more convenient, preferable, and potentially less invasive, the findings from Akbari et al.‘s study suggest that both oral and SC insulin delivery methods offer similar effectiveness and safety profiles.

As for effectiveness, in the studies reviewed, most of them (11 out of 18) demonstrated either equal tolerability or more tolerability of TD insulin compared to SC insulin. This suggests that patients may experience fewer adverse effects or discomfort with TD insulin delivery, making it a more acceptable option for some individuals. Specifically, eleven studies showed equal tolerability between TD and SC insulin, indicating that TD insulin is at least as well-tolerated as SC insulin in terms of side effects, injection site reactions, and overall patient comfort. Additionally, seven studies reported greater tolerability of TD insulin than SC insulin, indicating that TD insulin may offer a more favorable experience for patients in terms of tolerability and acceptance.

The preference for TD insulin delivery over traditional SC delivery was also assessed in the studies. Most of the studies (11 out of 18) showed a higher preference for TD insulin delivery, suggesting that patients may prefer the convenience, ease of use, and potentially reduced invasiveness of TD insulin administration. On the other hand, six studies reported equal preferability for TD insulin versus SC insulin, indicating that some patients may not have a strong preference for one method over the other. Only one study showed that TD insulin delivery was less preferable than SC insulin. This outlier suggests that individual preferences and experiences with different insulin delivery methods can vary among patients.

The potential advantages of TD insulin, such as improved tolerability, higher preference among patients, and potentially enhanced convenience, make it a promising alternative to traditional SC insulin administration. Further research and clinical trials are needed to confirm these findings and explore the long-term benefits and outcomes of TD insulin delivery in diabetes management. Besides that, TD systems have the advantage of reducing dosing frequency as drugs are released at a predetermined rate and controlling blood glucose levels over a prolonged period of time, contributing to better patient compliance [65].

In addition to their superior effectiveness and safety, TD insulin delivery should preferably be highly considered because improved patient compliance would ultimately lead to reduced healthcare costs for diabetes patients due to the potential lower frequency of hypo- and hyperglycemic events and related hospitalizations. As indicated previously, MN has been used to extract interstitial fluid from human subjects to successfully detect glucose levels [66]. Further research and clinical trials are needed to confirm these findings and explore the long-term benefits of TD insulin delivery for individuals with diabetes. To ensure the reliability and dependability of the results and enable stronger inferences to be made, a larger sample size is essential. To increase the generalizability of the findings, a more varied study sample must be assembled, comprising people with various socioeconomic, ethnic, and geographic backgrounds. Additionally, examining the safety and effectiveness of the alternate delivery method in distinct patient subgroups, such as children, the elderly, or individuals with certain comorbidities, will offer important information on its generalizability to a range of demographics. To guarantee the safety and effectiveness of this delivery mechanism over time, it is important to investigate any potential problems and effects over time. Finally, carrying out comparative analyses that assess this method’s efficacy in comparison to conventional delivery methods will facilitate a thorough comprehension of its advantages and disadvantages, ultimately contributing to evidence-based decision-making.

Conclusion

This is the first systematic review of the effectiveness, safety, and preference of TD insulin delivery in comparison with SC insulin delivery, considering clinical trials. Although for many years the only choice of insulin delivery was SC delivery, in recent years there have been various novel-based studies on oral and TD insulin delivery. These TD-based insulin delivery methods found that TD insulin delivery methods were the best alternative because most of them were more effective, safe, and preferable over SC delivery. If they are not more effective, safe, and preferable, at least they are equally effective, safe, and preferable with SC insulin delivery. By considering this, further clinical trials should be conducted with a larger sample size to ensure the effectiveness and safety of this type of delivery, ultimately making it a practical and accessible option for patients.

Data availability

The datasets used during the current study are included in the manuscript.

Abbreviations

AEs:

Adverse events

AUC:

Area under the curve

BG:

Blood glucose

Cmax:

Maximum concentration

DM:

Diabetes mellitus

FBG:

Fasting blood glucose

IA:

Insulin aspart

ID:

Intradermal

IL:

Insulin lispro

MDBG:

Mean daily blood glucose

MNs:

Microneedles

NFII:

Needle-free insulin injector

PD:

Pharmacodynamic

PK:

Pharmacokinetic

PPG:

Postprandial glucose

QOL:

Quality of life

RHI:

Regular human insulin

SC:

Subcutaneous

T1D:

Type 1 diabetes

T2D:

Type 2 diabetes

TBR:

Time below range

TDDDS:

Transdermal drug delivery systems

TIR:

Time in range

Tmax:

Time to reach maximum concentration

References

  1. Zhang Y, Yu J, Kahkoska AR, Wang J, Buse JB, Gu Z. Advances in transdermal insulin delivery. Adv Drug Deliv Rev. 2019;139:51–70.

    Article  CAS  PubMed  Google Scholar 

  2. Veiseh O, Tang BC, Whitehead KA, Anderson DG, Langer R. Managing diabetes with nanomedicine: challenges and opportunities. Nat Rev Drug Discov. 2015;14(1):45–57.

    Article  CAS  PubMed  Google Scholar 

  3. Afsaneh E, Sharifdini A, Ghazzaghi H, Ghobadi MZ. Recent applications of machine learning and deep learning models in the prediction, diagnosis, and management of diabetes: a comprehensive review. Diabetes Metab Syndr. 2022;14(1):1–39.

    Google Scholar 

  4. Hoyer A, Brinks R, Tönnies T, Saydah SH, D’Agostino RB Jr, Divers J, Isom S, Dabelea D, Lawrence JM, Mayer-Davis EJ, Pihoker C. Estimating incidence of type 1 and type 2 diabetes using prevalence data: the SEARCH for diabetes in Youth study. BMC Med Res Methodol. 2023;23(39):1–8.

    Google Scholar 

  5. Hu S, Su X, Fan G. Efficacy and tolerability of the Subcutaneous Semaglutide for type 2 diabetes patients: an updated systematic review and meta-analysis. Diabetes Metab Syndr. 2023;15(218):1–11.

    CAS  Google Scholar 

  6. Wang XM, Zhong SP, Li GF, Zhuge FY. Diabetes duration or age at onset and mortality in insulin-dependent diabetics: a systematic review and meta-analysis. Diabetes Metab Syndr. 2023;15(147):1–10.

    Google Scholar 

  7. Nordquist L, Roxhed N, Griss P, Stemme G. Novel microneedle patches for active insulin delivery are efficient in maintaining glycaemic control: an initial comparison with subcutaneous administration. Pharm Res. 2007;24:1381–8.

    Article  CAS  PubMed  Google Scholar 

  8. Gitelman SE, Bundy BN, Ferrannini E, Lim N, Blanchfield JL, DiMeglio LA, Felner EI, Gaglia JL, Gottlieb PA, Long SA, Mari A. Imatinib therapy for patients with recent-onset type 1 diabetes: a multicentre, randomised, double-blind, placebo-controlled, phase 2 trial. Lancet Diabetes Endocrinol. 2021;9(8):502–14.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  9. Olorunsola EO, Udoh IE, Ekott MB, Alozie MF, Davies KG. Biopharmaceutics and clinical outcomes of emerging dosage forms of insulin: a systematic review. Diabet Epidemiol Manag. 2023;9:1–7.

    Article  Google Scholar 

  10. Qiu Y, Qin G, Zhang S, Wu Y, Xu B, Gao Y. Novel lyophilized hydrogel patches for convenient and effective administration of microneedle-mediated insulin delivery. Int J Pharm. 2012;437(1–2):51–6.

    Article  CAS  PubMed  Google Scholar 

  11. Kang SL, Hwang YN, Kwon JY, Kim SM. Effectiveness and safety of a model predictive control (MPC) algorithm for an artificial pancreas system in outpatients with type 1 diabetes (T1D): systematic review and meta-analysis. Diabetes Metab Syndr. 2022;14(187):1–12.

    Google Scholar 

  12. Godoi A, Reis Marques I, Padrão EM, Mahesh A, Hespanhol LC, Riceto Loyola Júnior JE, de Souza IA, Moreira VC, Silva CH, Miyawaki IA, Oommen C. Glucose control and psychosocial outcomes with use of automated insulin delivery for 12 to 96 weeks in type 1 diabetes: a meta-analysis of randomised controlled trials. Diabetes Metab Syndr. 2023;15(190):1–18.

    Google Scholar 

  13. Heise T. The future of insulin therapy. Diabetes Res Clin Pract. 2021;175:1–10.

    Article  Google Scholar 

  14. Cheung KK, Senior PA. Novel and emerging insulin preparations for type 2 diabetes. Can J Diabetes. 2015;39:S160–6.

    Article  PubMed  Google Scholar 

  15. Sugumar V, Ang KP, Alshanon AF, Sethi G, Yong PV, Looi CY, Wong WF. A comprehensive review of the evolution of insulin development and its delivery method. Pharmaceutics. 2022;14(7):1–28.

    Article  Google Scholar 

  16. Hussain M, Hafeez A, Kushwaha SP. Nanoformulation mediated transdermal delivery of anti-diabetic drugs: an updated review. Intell Pharm. 2023;1(4):192–200.

    Google Scholar 

  17. Roy L, Bhattacharjee M. Overview of novel routes of insulin: current status. Int J Adv Med. 2020;7(10):1597–602.

    Article  Google Scholar 

  18. Sibiya N, Mbatha B, Ngubane P, Khathi A. Celebrating a century of insulin Discovery: a critical Appraisal of the emerging alternative insulin Delivery systems. Curr Drug Deliv. 2023;20(6):656–68.

    Article  CAS  PubMed  Google Scholar 

  19. Verma A, Kumar N, Malviya R, Sharma PK. Emerging trends in noninvasive insulin delivery. J Pharm. 2014; 1–10.

  20. Limenh LW. A review on oral novel delivery systems of insulin through the novel delivery system formulations: a review. SAGE Open Med. 2024;12:1–11.

    Article  Google Scholar 

  21. Zhao J, Xu G, Yao X, Zhou H, Lyu B, Pei S, Wen P. Microneedle-based insulin transdermal delivery system: current status and translation challenges. Drug Deliv Transl Res. 2022;12(10):2403–27.

    Article  CAS  PubMed  Google Scholar 

  22. Sugumar V, Hayyan M, Madhavan P, Wong WF, Looi CY. Current development of chemical penetration enhancers for transdermal insulin delivery. Biomedicines. 2023;11(664):1–25.

    Google Scholar 

  23. Iliopoulos F, Sil BC, Evans CL. The role of excipients in promoting topical and transdermal delivery: current limitations and future perspectives. Front Drug Deliv. 2022;2:1049848.

    Article  Google Scholar 

  24. Limenh LW. Advances in the transdermal delivery of antiretroviral drugs. SAGE Open Med. 2024;12:1–9.

    Article  Google Scholar 

  25. Kumar R, Philip A. Modified transdermal technologies: breaking the barriers of drug permeation via the skin. TJPR. 2007;6(1):633–44.

    Google Scholar 

  26. Li YZ, Quan YS, Zang L, Jin MN, Kamiyama F, Katsumi H, Yamamoto A, Tsutsumi S. Transdermal delivery of insulin using trypsin as a biochemical enhancer. Biol Pharm Bull. 2008;31(8):1574–9.

    Article  CAS  PubMed  Google Scholar 

  27. Sadeqi A, Kiaee G, Zeng W, Rezaei Nejad H, Sonkusale S. Hard polymeric porous microneedles on stretchable substrate for transdermal drug delivery. Sci Rep. 2022;12(1):1–10.

    Article  Google Scholar 

  28. Nguyen HX, Nguyen CN. Microneedle-mediated transdermal delivery of biopharmaceuticals. Pharmaceutics. 2023;15(277):1–35.

    CAS  Google Scholar 

  29. Lai-Cheong JE, McGrath JA. Structure and function of skin, hair and nails. Medicine. 2013;41(6):317–20.

    Article  Google Scholar 

  30. Matteucci E, Giampietro O, Covolan V, Giustarini D, Fanti P, Rossi R. Insulin administration: present strategies and future directions for a noninvasive (possibly more physiological) delivery. Drug Des Devel Ther. 2015;9:3109–18.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  31. Hofmann E, Schwarz A, Fink J, Kamolz LP, Kotzbeck P. Modelling the complexity of human skin in vitro. Biomedicines. 2023;11(794):1–17.

    CAS  Google Scholar 

  32. Wickett RR, Visscher MO. Structure and function of the epidermal barrier. Am J Infect Control. 2006;34(10):S98–110.

    Article  Google Scholar 

  33. Matsui T, Amagai M. Dissecting the formation, structure and barrier function of the stratum corneum. Int Immunol. 2015;27(6):269–80.

    Article  CAS  PubMed  Google Scholar 

  34. Jeong WY, Kwon M, Choi HE, Kim KS. Recent advances in transdermal drug delivery systems: a review. Biomater Res. 2021;25(24):1–15.

    Google Scholar 

  35. Avcil M, Çelik A. Microneedles in Drug Delivery: Progress and challenges. Micromachines. 2021;12(1321):1–15.

    Google Scholar 

  36. Andrews S, Lee JW, Choi SO, Prausnitz MR. Transdermal insulin delivery using microdermabrasion. Pharm Res. 2011;28:2110–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  37. Prausnitz MR, Langer R. Transdermal drug delivery. Nat Biotechnol. 2008;26(11):1261–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  38. Zhang N, Zhou X, Xie H, Yang Z. Dissolving polymer microneedles for transdermal delivery of insulin. Front Pharmacol. 2021;12:1–10.

    Google Scholar 

  39. Ahad A, Raish M, Bin Jardan YA, Al-Mohizea AM, Al-Jenoobi FI. Delivery of insulin via skin route for the management of diabetes mellitus: approaches for breaching the obstacles. Pharmaceutics. 2021;13(1):1–17.

    Article  Google Scholar 

  40. Waghule T, Singhvi G, Dubey SK, Pandey MM, Gupta G, Singh M, Dua K. Microneedles: a smart approach and increasing potential for transdermal drug delivery system. Biomed Pharmacother. 2019;109:1249–58.

    Article  CAS  PubMed  Google Scholar 

  41. He X, Sun J, Zhuang J, Xu H, Liu Y, Wu D. Microneedle system for transdermal drug and vaccine delivery: devices, safety, and prospects. Dose-Response. 2019;17(4):1–18.

    Article  Google Scholar 

  42. Mdanda S, Ubanako P, Kondiah PP, Kumar P, Choonara YE. Recent advances in microneedle platforms for transdermal drug delivery technologies. Polymers. 2021;13(2405):1–24.

    Google Scholar 

  43. Wong WF, Ang KP, Sethi G, Looi CY. Recent advancement of medical patch for transdermal drug delivery. Medicina. 2023;59(778 4):1–20.

    Google Scholar 

  44. Trimzi MA, Ham YB. A needle-free jet injection system for controlled release and repeated Biopharmaceutical Delivery. Pharmaceutics. 2021;13(1770):1–25.

    Google Scholar 

  45. Cohen Y, Cohen G, Tworowski D, Eretz-Kdosha N, Silberstein E, Fallik E, Poverenov E. Biocompatible nanocarriers for passive transdermal delivery of insulin based on self-adjusting N-alkylamidated carboxymethyl cellulose polysaccharides. Nanoscale Adv. 2022;4(9):2124–33.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  46. Bergenstal RM, Johnson ML, Aroda VR, Brazg RL, Dreon DM, Frias JP, Kruger DF, Molitch ME, Mullen DM, Peyrot M, Richter S. Comparing patch vs pen bolus insulin delivery in type 2 diabetes using continuous glucose monitoring metrics and profiles. J Diabetes Sci Technol. 2022;16(5):1167–73.

    Article  CAS  PubMed  Google Scholar 

  47. Bohannon N, Bergenstal R, Cuddihy R, Kruger D, List S, Massaro E, Molitch M, Raskin P, Remtema H, Strowig S, Whitehouse F. Comparison of a novel insulin bolus-patch with pen/syringe injection to deliver mealtime insulin for efficacy, preference, and quality of life in adults with diabetes: a randomized, crossover, multicenter study. Diabetes Technol Ther. 2011;13(10):1031–7.

    Article  PubMed  PubMed Central  Google Scholar 

  48. Pettis RJ, Hirsch L, Kapitza C, Nosek L, Hövelmann U, Kurth HJ, Sutter DE, Harvey NG, Heinemann L. Microneedle-based intradermal versus subcutaneous administration of regular human insulin or insulin lispro: pharmacokinetics and postprandial glycemic excursions in patients with type 1 diabetes. Diabetes Technol Ther. 2011;13(4):443–50.

    Article  PubMed  Google Scholar 

  49. Gupta J, Felner EI, Prausnitz MR. Minimally invasive insulin delivery in subjects with type 1 diabetes using hollow microneedles. Diabetes Technol Ther. 2009;11(6):329–37.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  50. Norman JJ, Brown MR, Raviele NA, Prausnitz MR, Felner EI. Faster pharmacokinetics and increased patient acceptance of intradermal insulin delivery using a single hollow microneedle in children and adolescents with type 1 diabetes. Pediatr Diabetes. 2013;14(6):459–65.

    Article  CAS  PubMed  Google Scholar 

  51. Rini CJ, McVey E, Sutter D, Keith S, Kurth HJ, Nosek L, Kapitza C, Rebrin K, Hirsch L, Pettis RJ. Intradermal insulin infusion achieves faster insulin action than subcutaneous infusion for 3-day wear. Drug Deliv Transl Res. 2015;5:332–45.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  52. Gupta J, Felner EI, Prausnitz MR. Rapid pharmacokinetics of intradermal insulin administered using microneedles in type 1 diabetes subjects. Diabetes Technol Ther. 2011;13(4):451–6.

    Article  PubMed  PubMed Central  Google Scholar 

  53. Pettis RJ, Ginsberg B, Hirsch L, Sutter D, Keith S, McVey E, Harvey NG, Hompesch M, Nosek L, Kapitza C, Heinemann L. Intradermal microneedle delivery of insulin lispro achieves faster insulin absorption and insulin action than subcutaneous injection. Diabetes Technol Ther. 2011;13(4):435–42.

    Article  CAS  PubMed  Google Scholar 

  54. McVey E, Hirsch L, Sutter DE, Kapitza C, Dellweg S, Clair J, Rebrin K, Judge K, Pettis RJ. Pharmacokinetics and postprandial glycemic excursions following insulin lispro delivered by intradermal microneedle or subcutaneous infusion. J Diabetes Sci Technol. 2012;6(4):743–54.

    Article  PubMed  PubMed Central  Google Scholar 

  55. Kochba E, Levin Y, Raz I, Cahn A. Improved insulin pharmacokinetics using a novel microneedle device for intradermal delivery in patients with type 2 diabetes. Diabetes Technol Ther. 2016;18(9):525–31.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  56. Ji L, Gao L, Chen L, Wang Y, Ma Z, Ran X, Sun Z, Xu X, Wang G, Guo L, Shan Z. Insulin delivery with a needle-free insulin injector versus a conventional insulin pen in Chinese patients with type 2 diabetes mellitus: a 16-week, multicenter, randomized clinical trial (the FREE study). EClinicalMedicine. 2020;23:1–8.

    Article  Google Scholar 

  57. Jin X, Han J, Guan Q, Zhang X. A clinical observation study on the effect of needle-free insulin syringe on blood glucose control and well-being index in patients with early-onset type 2 diabetes mellitus. Front Endocrinol. 2023;14:01–7.

    Article  Google Scholar 

  58. Xing Y, Xie X, Xu J, Liu J, He Q, Yang W, Zhang N, Li X, Wang L, Fu J, Zhou J. Efficacy and safety of a needle-free injector in Chinese patients with type 2 diabetes mellitus treated with basal insulin: a multicentre, prospective, randomised, crossover study. Expert Opin Drug Deliv. 2019;16(9):995–1002.

    Article  CAS  PubMed  Google Scholar 

  59. Wu Q, Deng M, Wang W, Pan Q, Guo L. A self-controlled, cross-over study of intensive insulin treatment with needle-based injection versus needle-free injection in hospitalized patients with type 2 diabetes. Front Endocrinol. 2023;14:1162176.

    Article  Google Scholar 

  60. Guo L, Xiao X, Sun X, Qi C. Comparison of jet injector and insulin pen in controlling plasma glucose and insulin concentrations in type 2 diabetic patients. Medicine. 2017;96(1):1–5.

    Article  Google Scholar 

  61. Reutens AT, Balkau B, Cohen N. A pilot study to examine the tolerability and device preference in type 1 diabetes of insulin aspart administered by InsuJet compared with subcutaneous injection. Diabetes Technol Ther. 2014;16(4):235–40.

    Article  CAS  PubMed  Google Scholar 

  62. De Wit HM, Engwerda EE, Tack CJ, De Galan BE. Insulin administered by needle-free jet injection corrects marked hyperglycaemia faster in overweight or obese patients with diabetes. Diabetes Obes Metab. 2015;17(11):1093–9.

    Article  PubMed  Google Scholar 

  63. Engwerda EE, Tack CJ, De Galan BE. Needle-free jet injection of rapid-acting insulin improves early postprandial glucose control in patients with diabetes. Diabetes Care. 2013;36(11):3436–41.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  64. Barolet D, Benohanian A. Current trends in needle-free jet injection: an update. Clin Cosmet Investig Dermatol. 2018;11:231–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  65. Ng LC, Gupta M. Transdermal drug delivery systems in diabetes management: a review. Asian J Pharm Sci. 2020;15(1):13–25.

    Article  PubMed  Google Scholar 

  66. Wang PM, Cornwell M, Prausnitz MR. Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles. Diabetes Technol Ther. 2005;7:131–41.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to express their gratitude to the researchers behind the articles that have been published.

Funding

No funding was received.

Author information

Authors and Affiliations

Authors

Contributions

LWL, NKW, MM, and DE contributed to the definition of the research design, data analysis, manuscript drafting, and significant revisions. ETF, MH, AA, and MGM contributed to the manuscript’s drafting and crucial edits. In addition to offering scientific advice, LWL, TED, and AMD took part in defining the study design, writing the manuscript, and making important edits. The final manuscript was read and approved by all authors.

Corresponding author

Correspondence to Liknaw Workie Limenh.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Limenh, L.W., Worku, N.K., Melese, M. et al. Effectiveness, safety, and preference of transdermal insulin compared to subcutaneous insulin in the treatment of diabetes patients: a systematic review of clinical trials. Diabetol Metab Syndr 16, 197 (2024). https://doi.org/10.1186/s13098-024-01442-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13098-024-01442-5

Keywords