Use of continuous glucose monitoring in insulin-treated older adults with type 2 diabetes
Diabetology & Metabolic Syndrome volume 15, Article number: 240 (2023)
Abstract
Background
Few studies have reported the adherence to and efficacy of continuous glucose monitoring (CGM) for improving diabetes management in insulin-treated older adults with type 2 diabetes mellitus (T2DM).
Methods
Prospective observational cohort study using FreeStyle Libre Flash CGM in insulin-treated adults > 65 years with T2DM and HbA1c between 7% and 9%. The participants wore the CGM during the 6-weeks study period. The primary outcome was time in range (TIR) between 70 and 180 mg/dL. Secondary outcomes included time below range (TBR), glycemic variability (GV), adherence, and use of glucose data for self-insulin adjustment. Linear regressions with random effects verified the changes in TBR, TIR, time above range (TAR), GV, and GMI across the three visits using CGM (baseline, 4 weeks and 6 weeks), controlled for sex, age, educational level, and health system (private or public).
Results
A total of 66 participants completed the six weeks of CGM (age 72·8 ± 5·3 years; BMI 27·8 ± 3·6 kg/m2), HbA1c: 8·0 ± 0·6%, with an overall sensor utilization of 93·1 ± 6·0%. We observed a stability in TIR (baseline: 63.5 ± 18.9% vs. endpoint: 65.5 ± 18.8%; β = 1,0, p = 0.190). Despite the low TBR at the baseline, we observed statistically significant reduction over the study period (baseline: 5.8 ± 7.0% vs. endpoint: 3.8 ± 4.7%; (β=-1.00, p = 0.008). Glucose variability also reduced from the baseline (34.9 ± 7.2%) to the endpoint (33.0 ± 6.8%) (β=-0.99, p = < 0.001).
Conclusion
FreeStyle Libre Flash CGM is well accepted by older adults with T2DM and allows participants to make therapeutic decisions to reduce TBR and glycemic variability.
Introduction
The prevalence of diabetes increases with age, reaching 26.8% among subjects aged 65 years and older [1]. The aging of the world’s population has increased the proportion of those with diabetes over the age of 60 years [2]. Given the heterogeneity of older individuals with type 2 diabetes mellitus (T2DM), an individualized approach is warranted to avoid overtreatment and hypoglycemia in frail older individuals and the undertreatment of otherwise healthy [3].
Increased duration of diabetes is associated with reduced ß cell mass, which leads to insulin deficiency and the need for insulin therapy to achieve glycemic control in many older adults with long-standing T2DM [4, 5]. Insulin therapy, however, increases the risk of hypoglycemia, which is associated with adverse clinical outcomes. Clinical guidelines have recommended higher HbA1c targets for older adults than for younger adults to avoid hypoglycemia, based on safety concerns [6, 7].
A recent study using continuous glucose monitoring (CGM) in older individuals (> 69 years) with poor glycemic control (HbA1c > 8.0%) reported a frequency of hypoglycemic episodes (< 50 mg/dL) in about half of insulin-treated T2DM [8]. Hypoglycemic episodes are difficult to diagnose in older adults and are easily missed by intermittent finger stick measurements [9]. Unfortunately, older adults (≥ 65 years) are underrepresented in clinical trials, [10, 11] and there are limited data regarding the benefit and adherence of CGM in older adults with T2DM [12].
This study aimed to evaluate adherence to and efficacy of CGM in improving diabetes management in insulin-treated older adults with T2DM.
Methods
Study design and participants
This prospective observational cohort study was registered at ClinicalTrials.gov (NCT04411277). The local institutional review board (IRB) at Universidade Positivo approved the protocol and provided informed consent. Participants were identified by medical records from the Hospital da Cruz Vermelha Brasileira-Filial do Paraná and neuro geriatrician and endocrinology private clinic. Individuals were invited to participate by phone, and interested participants were referred to the Cline Research Center where the study procedures were carried out. Thus, the sample included patients from both public and private health systems.
Data collection process
At the first clinic visit to the research center, after signing an informed consent form, the participants were evaluated for their educational level and presence of comorbidities, including cardiovascular disease, hypertension, and dyslipidemia. Microvascular complications were assessed by a previous eye examination for the presence of retinopathy, foot examination for neuropathy, and the estimated glomerular filtration rate (eGFR) was calculated using the CKD-EPI formula.
Screening for the presence of sarcopenia was performed using the SARC-F questionnaire, measuring muscle strength with grip strength using the Saehan dynamometer, and the functional test of getting up from the chair without the support of arms and walking for 3 m, turning 180º, then returning to the sitting position. In addition, body composition analysis using InBody 270 multifrequency bioimpedance was used to calculate appendicular skeletal muscle mass.
Inclusion criteria were age > 65 years, a history of T2DM, BMI between 18·5 and 35 kg/m², HbA1c between 7% and 9%, a stable diabetes medication regimen and body weight over the prior three months, and treatment with insulin and with or without oral agent treatment.
We excluded subjects diagnosed with type 1 diabetes, taking glucagon-like peptide 1 receptor agonists, eGFR < 30 ml/min/1.73 m², anemia (hemoglobin < 11 g), chronic liver disease (ALT > 3x upper limits of normal), use of glucocorticoids within three months prior to the study period, history of neoplasia treatment, and inability by the patient or caretaker to commit to the CGM instructions.
Eligible patients had a CGM sensor (FreeStyle Libre Flash CGM system, Abbott Diabetes Care) inserted for the first time in the posterior upper arm and were recommended to undergo CGM as many times as possible during the day, avoiding scan intervals longer than 8 h. Participants were instructed to return to the research center every 2 weeks, where the CGM data were downloaded and glucose reports were generated for review by the primary provider. CGM monitoring was performed for six consecutive weeks. The first two weeks were considered the baseline, the next two weeks were follow-up 1, and the final two weeks were considered the endpoint.
The research team and healthcare professionals were instructed not to change the treatment regimen except for safety reasons, and in this case, the participants were excluded from data analysis.
Outcomes measures
The primary outcome was time in range (TIR) between 70 and 180 mg/dL, and secondary outcomes were time below range (TBR) (< 70 mg/dL and < 54 mg/dL), time above range (TAR) (> 180 mg/dL, and > 250 mg/dL), glucose variability (GV) (calculated by % coefficient of variation, %CV = standard deviation (SD)/mean glucose x 100%), and adherence to CGM use (the percentage of captured sensor data). TIR, TBR, and TAR were expressed as percentages of the time per day. We also evaluated the prevalence of TIR ≥ 70% of the day, TBR (< 70 mg/dL) > 4% of the day, TBR (< 54 mg/dL) > 1% of the day, TAR (> 180 mg/dL) > 25% of the day, TAR (> 250 mg/dL) > 5% of the day, and the GV > 36% for each timepoint of the study (baseline, follow-up 1, and endpoint).
Statistical analysis
We used measures of central tendency (mean and median), variability (SD, interquartile range (IQR)), absolute (n), and relative (%) frequencies to describe participant characteristics and glucose profiles. A set of eight linear regressions with random intercept (participants) and slopes (time points) verified the changes in TBR (Overall: <70 mg/dL; TBR 1 (54–70 mg/dL, and TBR 2 (< 54 mg/dL)), TIR, TAR (> 180–250 mg/dL and > 250 mg/dL), GV, and glucose management indicator (GMI) across the three time points (baseline, follow-up 1 and endpoint) controlled by gender, age, educational level, and health system (private or public). We further explored the covariance between the intercept and slope to identify the influence of baseline values on the changes over time. The results were expressed in regression coefficients (β) and 95% confidence intervals (95% CI). The statistical significance was set at p < 0.05. The sample size showed a power of 0.80 to identify regression coefficients equal to or higher than ± 0.43 with an alpha of 95%. All statistical analyses were performed using Stata MP 14.1.
Results
From August 2020 to April 2022, 456 potential participants were invited to participate in the study by phone. A total of 140 subjects completed their 1st visit to undergo a detailed medical history, physical examination, assessment of diabetes complications, sarcopenia, and laboratory tests. The exclusion criteria eliminated 49.3% of the participants, leaving 71 eligible participants to start the CGM program. Five subjects did not have valid sensor data (< 70% readings) and were excluded from the final analysis. (Fig. 1) Participants who did not have valid sensor data were mainly female with a mean age of 71·4 ± 7·5 years. There were no significant differences in the clinical characteristics between the dropout participants and those included in the final analysis (p > 0·05).
Baseline clinical characteristics
Table 1 presents the baseline patient characteristics. The sample was equally composed of females and males (50%), with a mean age of 72.5 ± 5.3 years, a mean T2DM duration of 20 ±10.2 years, and a mean HbA1c of 7·9 ± 0·6%. The prevalence of obesity (BMI > 30 kg/m2) was 27.3%. A total of 39.4% reported regular physical exercise, 6.1% were smokers, and 28.9% consumed alcohol regularly. Regarding diabetes complications, 50% had been diagnosed with cardiovascular disease, 33.3% with heart failure, 18.2% with retinopathy, 36.4% with nephropathy, and 56.1% had peripheral neuropathy.
Table 2 shows information on diabetes treatment. Metformin was the most common oral antidiabetic drug (OAD) used by 78.8% of participants, and iSGLT2 was used by 22.7% of patients. Regarding the insulin regimen, 80% of the participants used human NPH (57.6%) or NPH + Regular (21.2%) formulations.
Sensor adherence
Overall, the sensor adherence reached 93%. Five (7.0%) participants had the CGM sensor capturing data less than 70% of the time at least in one CGM evaluation (baseline, follow-up 1 or endpoint).
The mean % time of the active sensor was > 91% for all the visits (overall: 92.6% ± 8.3). Sensor issues occurred in only 8% of the total sensors used (n = 213) (Table 3). There were 17 sensor issues; the most common problem was the sensor fall-offs, accidental pull-offs (n = 12, 70.0%). None of the patients experienced the skin symptoms/sensor-insertion events expected with device use (erythema, itching, and rash).
Glucose profile
Insulin-treated older adults at baseline had a median TIR of 67.0% (IQR = 52.0–77.0), median TBR of 4.9% (IQR = 1.0–7.0), median TAR (180–250 mg/dL) of 20.5% (IQR = 15.0–30.0), and median TAR (> 250 mg/dL) of 3.5% (IQR = 1.0–11.0). The mean glucose variability (GV) was 34.5% ± 7.2 and the mean GMI 7.0 ± 0.8. After six weeks of CGM, the median TIR was 70% (IQR = 57–76), TBR was 2% (IQR = 0–5), TAR (180–250 mg/dL) was 22% (IQR = 15–26), and TAR (> 250 mg/dL) was 3% (IQR = 1–9) (Fig. 2).
TIR ≥ 70% of the day occurred in 42.4% of the participants at the baseline and 51.5% at the endpoint. TBR (< 54 mg/dL) > 1 of the day occurred in 43.9% of the participants at the baseline and in 30.3% at the endpoint. TBR (54–70 mg/dL) > 4% of the day occurred in 50.0% of the participants at the baseline and in 30.3% at the endpoint. TAR (180–250 mg/dL) > 25% of the day occurred in 34.8% of the participants at the baseline and in 27.3% at the endpoint. TAR (> 250 mg/dL) > 5% of the day occurred in 42.4% of the participants at the baseline and in 39.4% at the endpoint. GV > 36% occurred in 40.9% of the participants at the baseline and in 25.7% at the endpoint (Fig. 3).
Table 4 shows the mean, SD, and regression coefficients for TIR, TBR, TAR, GV, and GMI changes during the study period. Significant changes were observed only in the TBR and GV. TBR (< 70 mg/dL) decrease on average 1% (95% CI= -1.75; -0.26, p = 0.008), TBR 1 (54–70 mg/dL) decreased on average 0.57% (95% CI= -1.01; -0.13, p = 0.012), TBR 2 (< 54 mg/dL) decreased on average 0.43% (95% CI= -0.83; -0.03, p = 0.035). GV decreased by 0.99% (95% CI= -1.53; -0.44, p < 0.001) by visit. There was a negative covariance between the intercept and slope for both variables (TBR and GV), indicating that patients with higher TBR and GV values at baseline showed a greater reduction in these variables.
Discussion
This real-world observational study showed that insulin-treated older adults with T2DM or their caregivers were able to handle Libre Flash CGM regardless of schooling.
We observed stability in TIR from the baseline to the end of the study; despite statistical significance, the prevalence of TIR > 70% increased by 9.1 p.p., which might indicate clinically significant changes at the individual level. These data may bring the debate about the recommendation TIR > 50% as a goal to achieve in elderly patients [13]. Therefore, future interventional studies are required to address this issue.
In this study, hypoglycemic episodes were very low in participants with a mean age over 70 years old, a long duration of T2DM, insulin treatment, and a high prevalence of macrovascular complications since the first 14-day baseline CGM use. These results suggest that CGM use may help patient self-management, improve level 1 hypoglycemia detection, and prevent severe hypoglycemia. Older patients with T2DM are at particularly high risk of developing severe hypoglycemic episodes [9]. Further studies should be conducted using CGM as a tool to prevent hypoglycemic events in elderly insulin-treated patients.
Even without a formal diabetes Flash CGM self-management education program, TBR decreased over the 6 weeks in parallel with glycemic variability improvement from the baseline to the end of the study. The improved safety of insulin treatment in this high-risk group of patients is in line with a previous publication showing the use of flash CGM is associated with reduced diabetes events and hospitalizations in insulin treated T2DM [14]. We assumed that reductions in GV occurred mainly because of decreases in TBR, since TAR did not change over the study period. Skin integrity in the elderly was not an issue for Flash CGM use, and there were no transmission errors from the sensor. Older adults with T2DM whose sensor adherence was greater than 70% were able to make the correct decisions regarding glucose management. There have been few efficacy trials of real-time CGM involving insulin-treated older patients with T2DM [15]. Consequently, there is no official recommendation in the ADA’s Standards of Medical Care in Diabetes Technology-2023 for using CGM in insulin-treated older adults with T2DM [16].
This study demonstrates that Flash CGM is a good tool to improve diabetes care in older people, since they were able to make correct therapy decisions, experienced few sensor issues during the 6 weeks of the study, and none of them were related to subcutaneous conditions. This study has some limitations, including the small number of participants. The explanation for this is that the recruitment was done during the COVID-19 pandemic, and the study was conducted in a single center with a short-term follow-up. There were no data showing the glucose profile with blinded sensor wear, and the Freestyle Libre Pro was not available in Brazil at the time of this study. Larger clinical trials with longer durations are required to assess the persistent benefits of this intervention. In addition, the CGM sensor placement was performed at the center; therefore, we did not assess the elderly’s ability to manage it by themselves. Another limitation of the present study was the lack of data on the frequency of viewing instantaneous CGM information by patients. Future investigations should collect this information, because it may be related to better glycemic control.
Conclusion
The use of Flash CGM in older people with type 2 diabetes receiving insulin treatment is possible regardless of social conditions or schooling, improving the glycemic profile and safety in conditions of high risk of hypoglycemia.
Data Availability
The datasets used can be accessed from the Cline Research Center’s study source document file.
References
Centers for Disease Control and Prevention. National Diabetes Statistics Report., 2020: Estimates of Diabetes and its Burden in the United States [Internet]. 2021. Available from: https://www.cdc.gov/diabetes/pdfs/data/statistics/national-diabetes-statistics-report.pdf.
IDF Diabetes Atlas 10th edition [Internet]. 2021 Available from: https://diabetesatlas.org/idfawp/resourcefiles/2021/07/IDF_Atlas_10th_Edition_2021.pdf.
Schernthaner G, Schernthaner-Reiter MH. Diabetes in the older patient: heterogeneity requires individualization of therapeutic strategies. Diabetologia. 2018;61:1503–16. https://doi.org/10.1007/s00125-018-4547-9.
Steppel JH, Horton ES. Beta-cell failure in the pathogenesis of type 2 Diabetes Mellitus. Curr Diab Rep. 2004;4(3):169–75. https://doi.org/10.1007/s11892-004-0019-3.
Rosenstock J. Management of type 2 Diabetes Mellitus in the elderly: special considerations. Drugs Aging. 2001;18(1):31–44.
American Diabetes Association Professional Practice Committee. Older Adults: Standards of Medical Care in Diabetes [Internet]. 2022. Diabetes Care 2022;45(Suppl. 1):S195–S207. https://doi.org/10.2337/dc22-S013.
AGS Quick Guide to Diabetes Management in Older Adults [Internet]. 2021. https://geriatricscareonline.org/ProductAbstract/AGS-Quick-Guide-to-Diabetes-Management-in-Older-Adults/PC0011#.
Munshi MN, Segal AR, Suhl E, Staum E, Desrochers L, Sternthal A, et al. Frequent hypoglycemia among elderly with poor glycemic control. Arch Intern Med. 2011;171(4):362–4. https://doi.org/10.1001/archinternmed.2010.539.
Bremer JP, Jauch-Chara K, Hallschmid M, Schmid S, Schultes B. Hypoglycemia unawareness in older compared with middle-aged patients with type 2 Diabetes. Diabetes Care. 2009;32:1513–7.
Singh S, Bajorek B. Defining elderly in clinical practice guidelines for pharmacotherapy. Pharm Pract (Granada). 2014;12:489. https://doi.org/10.4321/s1886-36552014000400007PMC4282767.
Noah DF, Palmowski A, Palmowski Y, Boers M, Buttgereit F. Recruitment and Retention of Older people in Clinical Research: a systematic literature. Rev J Am Geriatr Soc. 2020;68:2955–63.
Haak T, Hanaire H, Ajjan RA, Hermanns N, Riveline J-P, Rayman G. Flash glucose-sensing technology as a replacement for blood glucose monitoring for the management of insulin-treated type 2 Diabetes: a multicenter, open-label randomized controlled trial. Diabetes Therapy. 2017;8:55–73.
Battelino B, and Associates. Clinical targets for continuous glucose Monitoring Data Interpretation: recommendations from the International Consensus on Time in Range. Diabetes Care. 2019;42:1593–603. https://doi.org/10.2337/dci19-0028.
Bergenstal RM, Kerr MSD, Roberts GJ, Souto D, Nabutovsky Y, Hirsch IB. Flash CGM is Associated with reduced Diabetes events and hospitalizations in insulin-treated type 2 Diabetes. J Endocr Soc. 2021;5(4):1–9. https://doi.org/10.1210/jendso/bvab013.
Karter AJ, Parker MM, Moffet HH, Gilliam LK, Dlott R. Association of real-time continuous glucose monitoring with glycemic control and acute metabolic events among patients with insulin-treated Diabetes. JAMA. 2021;325:2273–84.
American Diabetes Association Professional Practice Committee, |. Diabetes Technology: standards of Medical Care in Diabetes 2022. Diabetes Care. 2022;45(Suppl 1):97–S112. https://doi.org/10.2337/dc22-S007.
Acknowledgements
This study was supported by a grant from Abbott Diabetes Care. We would like to thank Editage (www.editage.com) for English language editing.
Funding
This research was supported by a grant from Abbott Diabetes Care for laboratory work, the FreeStyle Libre Flash interstitial glucose sensor and readers, and multifrequency bioimpedance.
Author information
Authors and Affiliations
Contributions
Silmara A O Leite:Conceptualization, Funding acquisition, Investigation, Writing. Michael P Silva: Data curation, Formal analysis, Study design. Ana C R Lavalle: Project Administration, Data collection, Patient recruitment. Maria C V Bertogy: Data collection, Patient recruitment. Murilo Bastos: Data curation, Formal analysis, Writing. Suelen C Vieira Kuklik: Data collection, Patient recruitment. Guillermo Umpierrez: Methodology, Funding acquisition, Review & Editing.
Corresponding author
Ethics declarations
Ethical approval
The Universidade Positivo Internal Review Board approved and published the protocol (approval number: 3.978.733) at Plataforma Brasil.
Competing interests
The sponsor had no influence in the writing of the manuscript or on the decision to submit it for publication.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Leite, S.A.O., Silva, M.P., Lavalle, A.C.R. et al. Use of continuous glucose monitoring in insulin-treated older adults with type 2 diabetes. Diabetol Metab Syndr 15, 240 (2023). https://doi.org/10.1186/s13098-023-01225-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s13098-023-01225-4